beautypg.com

Options and auxiliary equipment – MITSUBISHI ELECTRIC MR-J2S- CP User Manual

Page 270

background image

14 - 13

14. OPTIONS AND AUXILIARY EQUIPMENT

b) Control circuit terminal

POINT

Undertightening can cause a cable disconnection or malfunction.

Overtightening can cause a short circuit or malfunction due to damage to
the screw or the brake unit.

A

RES

PC

B

SD

BUE

C

MSG

SD

MSG

SD SD

Jumper

Terminal block

6mm

Sheath

Core

Wire the stripped cable after twisting to prevent the cable
from becoming loose. In addition, do not solder it.
Screw size: M3
Tightening torque: 0.5N m to 0.6N m
Cable size: 0.3mm

2

to 0.75 mm

2

Screw driver: Small flat-blade screwdriver
(Tip thickness: 0.4mm/Tip width 2.5mm)

(c) Crimping terminals for P and N terminals of servo amplifier

POINT

Always use recommended crimping terminals or equivalent since some

crimping terminals cannot be installed depending on the size.

Servo amplifier

Brake unit

Number of
connected

units

Crimping terminal

Applicable tool

Manufacturer

MR-J2S-350CP FR-BU2-15K 1

FR-BU2-15K 1

MR-J2S-500CP

FR-BU2-30K 1

FVD5.5-S4 YNT-1210S

Japan Solderless

Terminal

MR-J2S-700CP FR-BU2-30K 1