Options and auxiliary equipment – MITSUBISHI ELECTRIC MR-J2S- CP User Manual
Page 267

14 - 10
14. OPTIONS AND AUXILIARY EQUIPMENT
(2) Brake unit parameter setting
Normally, when using the FR-BU2, changing parameters is not necessary. Whether a parameter can
be changed or not is listed below.
Parameter
No. Name
Change
possible/
impossible
Remarks
0
Brake mode switchover
Impossible Do not change the parameter.
1
Monitor display data selection
Possible
Refer to the FR-BU2-(H) Brake Unit
Instruction Manual.
2
Input terminal function selection 1
3
Input terminal function selection 2
77
Parameter write selection
78 Cumulative
energization
time
carrying-over times
CLr Parameter
clear
ECL Alarm
history
clear
C1 For
manufacturer
setting
Impossible Do not change the parameter.