beautypg.com

Options and auxiliary equipment – MITSUBISHI ELECTRIC MR-J2S- CP User Manual

Page 267

background image

14 - 10

14. OPTIONS AND AUXILIARY EQUIPMENT


(2) Brake unit parameter setting

Normally, when using the FR-BU2, changing parameters is not necessary. Whether a parameter can
be changed or not is listed below.

Parameter

No. Name

Change

possible/

impossible

Remarks

0

Brake mode switchover

Impossible Do not change the parameter.

1

Monitor display data selection

Possible

Refer to the FR-BU2-(H) Brake Unit
Instruction Manual.

2

Input terminal function selection 1

3

Input terminal function selection 2

77

Parameter write selection

78 Cumulative

energization

time

carrying-over times

CLr Parameter

clear

ECL Alarm

history

clear

C1 For

manufacturer

setting

Impossible Do not change the parameter.