4. OPERATION

(b) ST1 coordinate system selection (parameter No.1)

Choose the servo motor rotation direction at the time when the forward rotation start (ST1) is
switched on.

Parameter No. 1 setting

Servo motor rotation direction

when forward rotation start (ST1) is switched on

0

CCW rotation with position data
CW rotation with position data

1

CW rotation with position data
CCW rotation with position data

CCW

CW

(c) Feed length multiplication selection (parameter No.1)

Set the unit multiplication factor (STM) of position data.

Parameter No.1 setting

Position data input range [mm]

0

999.999 to 999.999

1

9999.99 to 9999.99

2

99999.9 to 99999.9

3

999999 to 999999

(3) Operation

Choose the point table using DI0 to DI4 and short ST1-SG to perform positioning to the position data
under the conditions of the preset speed, acceleration time constant and deceleration time constant. At
this time, reverse rotation start (ST2) is invalid.

Item Setting

method

Description

Automatic operation mode selection

Automatic/manual selection (MD0)

MD0 is turned on.

Point table selection

Point table No. selection 1 (DI0)
Point table No. selection 2 (DI1)
Point table No. selection 3 (DI2)
Point table No. selection 4 (DI3)
Point table No. selection 5 (DI4)

Refer to section 4.2.1, (2).

Start

Forward rotation start (ST1)

Short ST1-SG (ON) to start.