beautypg.com

2 write commands, Communication functions – MITSUBISHI ELECTRIC MR-J2S- CP User Manual

Page 321

background image

15 - 14

15. COMMUNICATION FUNCTIONS


15.11.2 Write commands

(1) Status display (Command [8][1])

Command Data No.

Description

Setting range Frame length

[8][1] [0][0]

Status

display data clear

1EA5

4


(2) Parameter (Command [8][4])

Command Data No.

Description

Setting range Frame length

[8][4]

[0][0] to

[5][A]

Each parameter write
The decimal equivalent of the data No. value
(hexadecimal) corresponds to the parameter number.

Depends on

the parameter.

8


(3) External I/O signal (Command [9][2])

Command Data No.

Description

Setting range Frame length

[9][2] [6][0]

Communication input device signal

Refer to

section 15.12.5

8


(4) Alarm history (Command [8][2])

Command Data No.

Description

Setting range Frame length

[8][2] [2][0]

Alarm

history clear

1EA5

4


(5) Current alarm (Command [8][2])

Command Data No.

Description

Setting range Frame length

[8][2] [0][0]

Alarm reset

1EA5

4


(6) Point table/position data (Command [C][0])

Command Data No.

Description

Setting range Frame length

[C][0]

[0][1] to

[1][F]

Position data write
The decimal equivalent of the data No. value
(hexadecimal) corresponds to the Point table No.

999999 to

999999 8


(7) Point table/speed data (Command [C][6])

Command Data No.

Description

Setting range Frame length

[C][6]

[0][1] to

[1][F]

Speed data write
The decimal equivalent of the data No. value
(hexadecimal) corresponds to the Point table No.

0 to Permissible

instantaneous

speed

8


(8) Point table/acceleration time constant (Command [C][7])

Command Data No.

Description

Setting range Frame length

[C][7]

[0][1] to

[1][F]

Acceleration time constant write
The decimal equivalent of the data No. value
(hexadecimal) corresponds to the Point table No.

0 to 20000

8