beautypg.com

Operation – MITSUBISHI ELECTRIC MR-J2S- CP User Manual

Page 116

background image

4 - 25

4. OPERATION

(b) Using the input signals for setting

Set the pulse generator multiplication 1 (TP0) and pulse generator multiplication 2 (TP1) to the
input signals in "Device setting" on the MR Configurator (servo configuration software) (refer to
chapter 6).

(Note) Pulse generator

multiplication 2

(across TP1)

(Note) Pulse generator

multiplication 1

(across TP0)

Multiplication ratio of servo motor

rotation to manual pulse generator

rotation

Moving distance

0

0

Parameter No.1 setting valid

0 1 1

time

1[ m]

1 0

10

times

10[ m]

1 1

100

times

100[ m]

Note. 0: Open across TP1/TP0-SG
1: Shorted across TP1/TP0-SG


(4) Operation

Turn the manual pulse generator to rotate the servo motor. For the rotation direction of servo motor,
refer to (2) of this section.