14. OPTIONS AND AUXILIARY EQUIPMENT


(2) Connection example

(Note 3)
Power
supply

NFB

MC

Servo amplifier

L

11

L

21

L

1

L

2

L

3

Power regeneration
converter FR-RC

SK

ON

MC

B C

N

P

C

RDY

SE

Alarm
output

RDY
output

A

B

C

5m(16.4ft) or less

N/

P/

Operation ready

MC

OFF

EMG

RA2

FR-RC

Ready

Power factor improving reactor

FR-BAL

(Note 2)

Phase detection
terminals

B

C

R/L

1

S/L

2

T/L

3

RX

R

SX

S

TX

T

(Note 1)

ALM

COM

VDD

RA2

EMG

SON

SG

Note 1. When not using the phase detection terminals, fit the jumpers across RX-R, SX-S and TX-T. If the jumpers remain removed, the

FR-RC will not operate.

2. When using servo amplifiers of 5kW and 7kW, always remove the lead of built-in regenerative resistor connected to P terminal

and C terminal.

3. Refer to section 1.2 for the power supply specification.