beautypg.com

Outline dimension drawings – MITSUBISHI ELECTRIC MR-J2S- CP User Manual

Page 245

background image

12 - 4

12. OUTLINE DIMENSION DRAWINGS


(4) MR-J2S-500CP

2- 6( 0.24)
mounting hole

[Unit: mm]

([Unit: in])

C

N

2

C

N

3

C

N

1

A

C

N

1

B

OPEN

OPEN

C

N

2

C

N

3

C

N

1

A

C

N

1

B

OPEN

TE1

TE2

130(5.12)
118(4.65)

7.

5

(0

.5)

(0.24)

6

(0.24)

250(9.

84

)

235(9.

25

)

7.

5

(0

.5

)

6(0.24)

N.P.

Approx.70

(2.76)

6

(0

.7

9)

200(7.87)

(0.19) 5

Terminal layout

N.P.

Cooling fan

Cooling fan wind direction

MITSUBISHI

MITSUBISHI

A

ppro

x.

20

Servo amplifier

Mass

[kg]([lb])

MR-J2S-500CP 4.9(10.8)

TE1

TE2

L

11

L

21

N

L

1

L

2

L

3

C

P

U

V

W

Terminal screw : M4
Tightening torque : 1.2 [N m](10.6 [lb in])

PE terminals

Built-in regenerative resistor lead
terminal fixing screw

Terminal screw : M4
Tightening torque : 1.2 [N m](10[lb in])

Terminal screw : M3.5
Tightening torque : 0.8 [N m](7[lb in])

Mounting Screw
Screw Size:M5
Tightening torque:
3.24[N m]
(28.676 [lb in])

Terminal signal layout