beautypg.com

Signals and wiring – MITSUBISHI ELECTRIC MR-J2S- CP User Manual

Page 64

background image

3 - 15

3. SIGNALS AND WIRING


(3) In position

The following timing chart shows the relationship between the signal and the feedback pulse of the
servo motor. This timing can be changed using parameter No. 6 (in-position range). INP-SG are
connected in the servo-on status.

ON

OFF

ON

OFF

Forward rotation start (ST1)

or reverse rotation start (ST2)

Servo motor speed

In position (INP)

3ms or less

In-position range

When positioning operation is performed once

Forward rotation start (ST1)

or reverse rotation start (ST2)

ON

OFF

ON

OFF

Servo motor speed

In position (INP)

In-position range

3ms or less

Reverse

rotation

Forward

rotation

When servo motor reverses rotation direction during automatic continuous operation