15 - 12
15. COMMUNICATION FUNCTIONS
(4) Alarm history (Command [3][3])
Command
Data No.
Description
Alarm occurrence sequence
Frame length
[3][3]
[1][0]
Most recent alarm
4
[3][3]
[1][1]
First alarm in past
4
[3][3]
[1][2]
Second alarm in past
4
[3][3]
[1][3]
Third alarm in past
4
[3][3]
[1][4]
Fourth alarm in past
4
[3][3] [1][5]
Alarm number in alarm history
Fifth alarm in past
4
[3][3]
[2][0]
Most recent alarm
8
[3][3]
[2][1]
First alarm in past
8
[3][3]
[2][2]
Second alarm in past
8
[3][3]
[2][3]
Third alarm in past
8
[3][3]
[2][4]
Fourth alarm in past
8
[3][3] [2][5]
Alarm occurrence time in alarm
history
Fifth alarm in past
8
(5) Current alarm (Command [0][2] [3][5])
Command Data
No.
Description
Frame
length
[0][2]
[0][0]
Current alarm number
4
Command
Data No.
Description
Status display item
Frame length
[3][5] [8][0]
Current
position
12
[3][5] [8][1]
Command
position
12
[3][5]
[8][2]
Command remaining distance
12
[3][5]
[8][3]
Point table No.
12
[3][5]
[8][4]
Cumulative feedback pulses
12
[3][5] [8][5]
Servo
motor
speed
12
[3][5] [8][6]
Droop
pulses
12
[3][5] [8][7]
Override
12
[3][5] [8][8]
Torque
limit
voltage
12
[3][5] [8][9]
Regenerative load ratio
12
[3][5]
[8][A]
Effective load ratio
12
[3][5]
[8][B]
Peak load ratio
12
[3][5] [8][C]
Instantaneous
torque
12
[3][5] [8][D]
Within
one-revolution position
12
[3][5] [8][E]
ABS
counter
12
[3][5]
[8][F]
Load inertia moment ratio
12
[3][5] [9][0]
Status display data value and
processing information at alarm
occurrence
Bus voltage
12