beautypg.com

Communication functions – MITSUBISHI ELECTRIC MR-J2S- CP User Manual

Page 319

background image

15 - 12

15. COMMUNICATION FUNCTIONS


(4) Alarm history (Command [3][3])

Command

Data No.

Description

Alarm occurrence sequence

Frame length

[3][3]

[1][0]

Most recent alarm

4

[3][3]

[1][1]

First alarm in past

4

[3][3]

[1][2]

Second alarm in past

4

[3][3]

[1][3]

Third alarm in past

4

[3][3]

[1][4]

Fourth alarm in past

4

[3][3] [1][5]

Alarm number in alarm history

Fifth alarm in past

4

[3][3]

[2][0]

Most recent alarm

8

[3][3]

[2][1]

First alarm in past

8

[3][3]

[2][2]

Second alarm in past

8

[3][3]

[2][3]

Third alarm in past

8

[3][3]

[2][4]

Fourth alarm in past

8

[3][3] [2][5]

Alarm occurrence time in alarm
history

Fifth alarm in past

8


(5) Current alarm (Command [0][2] [3][5])

Command Data

No.

Description

Frame

length

[0][2]

[0][0]

Current alarm number

4

Command

Data No.

Description

Status display item

Frame length

[3][5] [8][0]

Current

position

12

[3][5] [8][1]

Command

position

12

[3][5]

[8][2]

Command remaining distance

12

[3][5]

[8][3]

Point table No.

12

[3][5]

[8][4]

Cumulative feedback pulses

12

[3][5] [8][5]

Servo

motor

speed

12

[3][5] [8][6]

Droop

pulses

12

[3][5] [8][7]

Override

12

[3][5] [8][8]

Torque

limit

voltage

12

[3][5] [8][9]

Regenerative load ratio

12

[3][5]

[8][A]

Effective load ratio

12

[3][5]

[8][B]

Peak load ratio

12

[3][5] [8][C]

Instantaneous

torque

12

[3][5] [8][D]

Within

one-revolution position

12

[3][5] [8][E]

ABS

counter

12

[3][5]

[8][F]

Load inertia moment ratio

12

[3][5] [9][0]

Status display data value and
processing information at alarm
occurrence

Bus voltage

12