Operation – MITSUBISHI ELECTRIC MR-J2S- CP User Manual
Page 110
4 - 19
4. OPERATION
(c) Absolute value command/incremental value command specifying system
This system is an auxiliary function for point tables to perform automatic operation by specifying
the absolute value command or incremental value command.
1) Positioning in single direction
The operation example given below assumes that the set values are as indicated in the following
table. Here, the point table No. 1 uses the absolute value command system, the point table No. 2
the incremental value command system, the point table No. 3 the absolute value system, and the
point table No. 4 the incremental value command system.
Point table
No.
Position data
[ 10
STM
m]
Servo motor
speed [r/min]
Acceleration time constant
[ms]
Deceleration time constant
[ms]
Dwell [ms]
(Note 1)
Auxiliary
function
1 5.00 3000
100
150
0 1
2 3.00 2000
Invalid
Invalid
0 3
3 10.00 1000
Invalid
Invalid
0 1
4 6.00 500
Invalid
Invalid
0
0
(Note 2)
Note 1. Always set "0".
2. Always set "0" or "2" to the auxiliary function of the last point table among the consecutive point tables.
0: When point table is used in absolute value command system
1: When point table is used in incremental value command system
ON
OFF
0
0
5.00
8.00
16.00
1
3.00
6.00
10.00
1
Acceleration time constant
of point table No. 1 (100)
Deceleration time constant
of point table No. 1 (150)
Speed
(2000)
Speed
(3000)
Speed
(1000)
Speed (500)
Servo motor speed
Forward
rotation
Position address
Selected point table No.
Forward rotation start
(ST1)
Point No. out put
(PT0 to PT4)