11 - 8

11. TROUBLESHOOTING

Display Name

Definition

Cause

Action

1. Machine struck something.

1. Review operation pattern.
2. Install limit switches.

2. Wrong connection of servo motor.

Servo amplifier's output terminals
U, V, W do not match servo motor's
input terminals U, V, W.

Connect correctly.

3. Servo system is instable and

hunting.

1. Repeat acceleration/deceleration to

execute auto tuning.

2. Change auto tuning response setting.
3. Set auto tuning to OFF and make gain

adjustment manually.

AL.51 Overload 2

Machine collision or
the like caused max.
For the time of the
alarm occurrence,
refer to the section
13.1.

4. Encoder faulty.

Checking method

When the servo motor shaft is
rotated with the servo off, the

cumulative feedback pulses do

not vary in proportion to the

rotary angle of the shaft but the

indication skips or returns midway.

Change the servo motor.

1. Acceleration/deceleration time

constant is too small.

Increase the acceleration/deceleration
time constant.

2. Internal torque limit 1 (parameter

No.28) is too small.

Increase the torque limit value.

3. Motor cannot be started due to

torque shortage caused by power
supply voltage drop.

1. Review the power supply capacity.
2. Use servo motor which provides larger

output.

4. Position control gain 1 (parameter

No.7) value is small.

Increase set value and adjust to ensure
proper operation.

5. Servo motor shaft was rotated by

external force.

1. When torque is limited, increase the

limit value.

2. Reduce load.
3. Use servo motor that provides larger

output.

6. Machine struck something.

1. Review operation pattern.
2. Install limit switches.

7. Encoder faulty

Change the servo motor.

AL.52 Error

excessive The

difference

between the model
position and the
actual servo motor
position exceeds 2.5
rotations. (Refer to
the function block
diagram in section
1.1.1)

8. Wrong connection of servo motor.

Servo amplifier's output terminals
U, V, W do not match servo motor's
input terminals U, V, W.

Connect correctly.

AL.61 Operation

alarm

"1" or more has been
set to auxiliary
function of point
table No. 31.

Setting mistake of auxiliary function
of point table No. 31.

Set "0" to auxiliary function of point table
No. 31.

1. Communication cable breakage.

Repair or change communication cable

2. Communication cycle longer than

parameter No. 23 setting.

Set correct value in parameter.

AL.8A Serial

communication
time-out error

RS-232C or RS-422
communication
stopped for longer
than the time set in
parameter No.23.

3. Wrong protocol.

Correct protocol.

1. Communication cable fault

(Open cable or short circuit)

Repair or change the cable.

AL.8E Serial

communication
error

Serial
communication
error occurred
between servo
amplifier and
communication
device (e.g. personal
computer).

2. Communication device (e.g.

personal computer) faulty

Change the communication device (e.g.
personal computer).

88888 Watchdog

CPU, parts faulty

Fault of parts in servo amplifier

Checking method

Alarm (88888) occurs if power is
switched on after disconnection
of all cables but the control
circuit power supply cables.

Change servo amplifier.