beautypg.com

2 list, Parameters – MITSUBISHI ELECTRIC MR-J2S- CP User Manual

Page 139

background image

5 - 2

5. PARAMETERS


5.1.2 List

POINT

The parameters marked * before their symbols are made valid by

switching power off once and then switching it on again after parameter
setting.


Refer to the corresponding reference items for details of the parameters.

(1) Item list

Class No.

Symbol

Name and Function

Initial value

Unit

Customer

setting

0 *STY

Command

system/regenerative

option

selection

0000

1 *FTY

Feeding

function

selection

0000

2

*OP1

Function selection 1

0002

3 ATU

Auto

tuning

0105

4

*CMX Electronic gear numerator

1

5

*CDV

Electronic gear denominator

1

6 INP

In-position

range

100 pulse

7

PG1

Position control gain 1

35

rad/s

8

*ZTY

Home position return type

0010

9

ZRF

Home position return speed

500

r/min

10 CRF

Creep

speed

10 r/min

11

ZST

Home position shift distance

0

m

12 CRP

Rough

match

output

range

0 10

STM

m

13 JOG

Jog

speed

100 r/min

14 *STC

S-pattern

acceleration/deceleration

time

constant

0

ms

15 *SNO

Station

number

setting

0

station

16

*BPS

Communication baud rate selection, alarm history clear

0000

17 MOD

Analog

monitor

output

0100

18 *DMD

Status

display

selection

0000

B

asi

c pa

ra

m

et

ers

19 *BLK

Parameter

write

inhibit

0000