6-1. INFORMATION MODE
5. REVIEW USAGE
FUNCTIONS (Continued)
Press to view the accumulated information since the data
was
manually
reset:
FUNCTION
DISPLAY
EX:
Day the usage data was previously reset
SINCE APR-19
Number of hours the fryer was on
PWR ON HRS 165
Total number of cook cycles
TOTAL CK 462
Cook Cycles stopped before “DONE”
QUIT COOK
4
Oil Wear based on Number of Cook Cycles
OIL WEAR ‘A’ 83%
Oil Wear based on Running Hours
OIL WEAR ‘B’ 55%
Cook Cycles for Product #1
COOKED -1L- 193
Cook Cycles for Product #2
COOKED -2L- 107
Cook Cycles for Product #3
COOKED -3L- 58
Cook Cycles for Product #4
COOKED -4L- 0
Cook Cycles for Product #5
COOKED -5L- 13
Cook Cycles for Product #6
COOKED -6L- 69
Cook Cycles for Product #1
COOKED -1R- 0
Cook Cycles for Product #2
COOKED -2R- 7
Cook Cycles for Product #3
COOKED -3R- 15
Cook Cycles for Product #4
COOKED -4R- 0
Cook Cycles for Product #5
COOKED -5R- 0
Cook Cycles for Product #6
COOKED -6R- 0
Reset usage data:
Enter the Usage Code (1, 2, 3 unless changed)
on this step to zero out all the usage information
RESET USG /
ENTER CODE ------
Press to continue to INP A_VHDSF_M.
6. INP A_VHDSFPM
Press to view the status of components and inputs. If the
input signal is detected, an identifying letter is displayed (see
below). If the signal is not detected, “_” is displayed.
With the COOK /PUMP switch in the COOK position, and
all inputs detected, “A_VHDSF_M” shows in the
display (“A_VHDSFP_” for gas units). See below for
definition of codes.
A = Power Switch in ON position.
V = Volts - 24 VAC detecte
H = HIGH LIMIT -- If "H" is present, the high limit is good.
If "H" is missing, the high limit is tripped out
(overheated) or disconnected.
D = DRAIN SWITCH-If “D” is
present, the drain handle is
closed. If “D” is missing, the drain is open or faulty.