Henny Penny OEA/OGA-323 User Manual
Page 41

Model OFE/OFG-321,322,323,324
3-12. FILTER PUMP PROBLEM
To help prevent filter pump problems:
PREVENTION
1.
Properly install paper envelope over the filter screens.
Fold the open end of the envelope, and clamp with retaining
clips so that crumbs cannot enter. Figure 3-6.
2.
Pump shortening, until no shortening is coming from the
nozzle.
Figure 3-6
3-13. FILTER PUMP MOTOR
In the event it overheats, the filter pump motor is equipped with a
PROTECTOR – MANUAL RESET
manual reset button located on the rear of the motor. After
waiting 5 minutes to allow the motor to cool, press the reset
button. It takes some effort to reset the motor. A screwdriver can
be used to help press reset button. Figure 3-7.
Servicing of the filter pump is done at the rear of the unit. If
service is required, disconnect the open fryer from the electrical
and/or gas power source, and pull the open fryer out from the
wall to gain access to rear.
Figure 3-7
To prevent burns caused by splashing shortening, turn
the unit's filter PUMP switch to the OFF position
before resetting the filter pump motor’s manual reset
protection
device.
3-14. CHANGING THE FILTER
The filter envelope should be changed after 10-12 filterings or
ENVELOPE
whenever it becomes clogged with crumbs. Proceed as follows:
The filter union could be hot. Wear protective glove or
cloth, or severe burns could result.
Use care to prevent burns caused by splashing of hot
shortening.
1.
Move the main POWER switch to the OFF position.
2.
Disconnect the filter union and remove the filter drain
pan from beneath the frypot.
703
3-21