1.
Connect the female quick disconnect, that is attached to the
hose in the rear of the open fryer, to the correct male quick
disconnect at the wall. Once attached, the hose can remain
connected unless the open fryer is moved.
Figures 3-8 & 3-9.
The hose is to be attached to shortening return
line only for the system to work properly.
Figure 3-8
2.
Open the drain valve and drop the shortening from the
desired frypot, into the filter drain pan.
3.
Pull diverter-handle towards you, in the back of the fryer,
from FILTER to DISCARD. Figure 3-10.
This handle could be hot! Use protective gloves or
Figure 3-9
cloth when turning diverter-handle, or burns could
result.
4.
Once all shortening is gone from frypot, turn the filter
pump switch to the ON position. Shortening is now
pumped from the filter drain pan.
Figure 3-10
3-26
703
3-17. OPERATING INSTRUCTIONS
FOR OPTIONAL DIRECT-
CONNECT SHORTENING
SYSTEM