4-3. SPECIAL PROGRAM
i. Press the UP or DOWN buttons to toggle from “NO” to
MODE (Continued)
“YES”. If “YES” is in the display, then during a time of
low volume, the operator can press the P6 button
(or P12) to manually enter the Idle mode.
Programming the idle on auto-lift open fryers, disables
the basket lift function of the P12 button.
Filter Tracking Enabled (SP-9)
The controls can be set to signal the operator when the
shortening needs filtering. The filter tracking must be
enabled to program the number of cook cycles between
filtering procedures. (See Filter Cycles in Product
Program
section.)
a. Follow steps 1 and 2 above.
b. Press and release the PROG button until “SP-9”
and “FILTER TRACKING ENABLED” flash on the
display, along with “1,OFF” on the right side of
the display.
c. To enable the filter tracking, press either the UP or DOWN
buttons to toggle the display from “1,OFF”, to
“2,MIXED”, “3,GLOBAL”, or “4,SCHED”
The “MIXED" option allows the operator to set
different amounts of Cook Cycles, between filters, for
each product. If the operator wants to have one setting
for all products, go to step g.
MIXED
d. If “2,MIXED” is selected, press the PROG button and
”SP-9A” shows in the display followed by
“SUGGEST FILTER AT …” and a value between 75%
and 100% on the right display. Press and release the
UP and DOWN arrows to change this value.