Henny Penny OEA/OGA-323 User Manual
Page 65

Model OFE/OFG-321,322,323,324
5-2. ERROR CODES
In the event of a control system failure, the digital
display shows an error message. The message codes
are shown in the DISPLAY column below. A constant
tone is heard when an error code is displayed, and to
silence this tone, press any button.
DISPLAY
CAUSE PANEL
BOARD
CORRECTION
“E-4”
Control board
Turn switch to OFF position, then turn switch back to ON;
overheating
if display shows “E-4”, the control board is getting too hot;
check the louvers on each side of the unit for obstructions
“E-5”
Shortening
Turn switch to OFF position, then turn switch back to ON;
overheating
if display shows “E-5”, the heating circuits and temperature
probe should be checked
“E-6A”
Temperature
Turn switch to OFF position, then turn switch back to ON;
probe open
if display shows “E-6A”, the temperature probe should be
checked; to replace, refer to Technical Manual
“E-6B”
Temperature
Turn switch to OFF position, then turn switch back to ON;
probe shorted
if display shows “E-6B”, the temperature probe should be
checked; to replace, refer to Technical Manual
“E-10”
High limit
Reset the high limit by manually pushing up on the red
reset button; if high limit does not reset, high limit must be
replaced; refer to Technical Manual
“E-15”
Drain switch
Close drain, using the drain valve handle. If display still
failure
shows “E-15”, check the drain microswitch; refer to
Technical
Manual
“E-41”,
Programming
Turn switch to OFF, then back to ON; if display shows any
“E-46”
failure
of the error codes, try to reinitialize the control (Special
Program Mode section); if error code persists, replace the
control board; refer to Technical Manual
“E-20A”
Air pressure
Press the Timer button to try the ignition process again;
switch failure
if “E-20A” persists check the air switch; refer to
(stuck
closed)
Technical
Manual
“E-20B”
Draft fan or
Press the Timer button to try the ignition process again;
air pressure
if “E-20B” persists, check the air switch or the blower
switch failure
motor; refer to Technical Manual
(stuck
open)
808 5-2