Henny Penny OEA/OGA-323 User Manual
Page 47

Model OFE/OFG-321,322,323,324
5.
Once all the shortening is out of the filter drain pan, turn the
filter pump switch to the OFF position.
6.
Push diverter-handle, in the back of the fryer, from
DISCARD to FILTER. Figure 3-11.
7.
Frypot is now ready for fresh shortening.
Figure 3-11
To light burner:
1. 1.
Turn the power switch to the OFF position.
2.
Rotate the gas control valve knob clockwise to the OFF
position and wait at least 5 minutes before continuing to
the next step.
3.
Rotate gas control valve counterclockwise to the ON
position.
4.
Place the power switch to the ON position.
5.
The burner will light and operate in a Melt Cycle
until the shortening reaches a preset temperature.
6.
Press the desired product button after the READY LED
illuminates.
To shutdown burner:
1.
Turn the power switch to the OFF position.
2.
Rotate gas control valve knob to the OFF position.
This fryer is equipped with a grounded (earthed) cord and plug for
your protection against shock, and should be plugged into a 3
prong grounded (earthed) receptacle. Do not cut or remove
grounding
prong.
208
3-27
3-17. OPERATING INSTRUCTIONS
FOR OPTIONAL DIRECT-
CONNECT SHORTENING
SYSTEM (Continued)
3-18. LIGHTING AND
SHUTDOWN OF THE
BURNERS