SECTION 5. TROUBLESHOOTING
5-1. TROUBLESHOOTING GUIDE
Problem Cause
Correction
POWER switch ON but fryer
• Open circuit
• Plug fryer in
completely inoperative
• Check breaker or fuse at supply
box
Shortening will not
• Open high limit
• Reset high limit per
heat but lights are on
circuit
High Temperature Limit
Error message “E-10”
Control section
• Drain valve open
• Turn drain valve handle to
Error message “E-15”
closed position
Foaming or boiling
• Water in shortening
• At end of cook cycle, drain
over of shortening
shortening and clean
• Improper or bad
• Use recommended shortening
shortening
• Improper filtering
• Refer to the procedure covering
filtering the shortening
• Improper rinsing after
• Clean and rinse the frypot, then
cleaning the fryer
dry thoroughly
Shortening will not
• Drain valve clogged
• Open valve, force cleaning
drain from frypot
with crumbs
brush through drain
Filter switch ON but
• Motor thermal
• Reset thermal switch per section
motor does not run
protector tripped
on Filter Pump Motor
Protector – Manual Reset
More detailed troubleshooting information is available at 1-800-417-8405 or 1-937-456-8405.