Henny Penny OEA/OGA-323 User Manual
Page 62

Model OFE/OFG-321,322,323,324
4-3. SPECIAL PROGRAM
e. If satisfied with code, press
PROG
. “*CODE CHANGE*”
MODE (Continued)
shows in display.
f. If not satisfied with code, press
INFO
and
*CANCELLED* shows in display, then reverts back to
"SP-16" and "CHANGE USG CODE ? 1=YES”. Then
the above steps can be repeated.
Change Shortening-A-Cook Cycles (SP-17)
The operator can set a reminder to filter the shortening, based
on the number of Cook Cycles accumulated. The display
shows “CHANGE OIL SOON” when the preset number of
Cook Cycles has been met, “OFF” to 5000, increments of 10.
a. Follow steps 1 and 2 above.
b.
Press
PROG
until "SP-17" and "CHANGE OIL’ A –
COOK CYCLES” shows in display, along with a number
of Cook Cycles.
c. Press and release UP and DOWN buttons to change the
number of Cook Cycles.
Change Shortening-B-Hours (SP-18)
The operator can set a reminder to filter the shortening, based
on the number of power-on hours accumulated. The display
shows “CHANGE OIL SOON” when the preset number of hours
has been met, “OFF” to 999 hours.
a. Follow steps 1 and 2 above.
b.
Press
PROG
until "SP-18" and "CHANGE OIL’ B –
HOURS” shows in display, along with a number of hours.
c. Press and release UP and DOWN buttons to change the
number of power-on hours.
Once the shortening is filtered, to clear the display of
“CHANGE OIL SOON” (SP-17 & SP-18), reset the
review usage data in the Information Mode. See
Information Mode section of this manual.
4-14