5-1. TROUBLE SHOOTING GUIDE
Problem Cause Correction
POWER switch ON but fryer
• Open circuit
• Plug fryer in
completely inoperative
• Check breaker or fuse at supply
box
Shortening will not
• Open high limit
• Reset high limit per
heat but lights are on.
circuit
High Limit Temperature
Error message “E10”
Control Section
• Drain valve open
• Turn drain valve handle to
Error message “E15”
closed position
Foaming or boiling
• Water in shortening
• At end of Cook Cycle, drain
over of shortening
shortening and clean
• Improper or bad
• Use recommended shortening
shortening
• Improper filtering
• Refer to the procedure covering
filtering the shortening
• Improper rinsing after
• Clean and rinse the frypot, then
cleaning the fryer
dry thoroughly
Shortening will not
• Drain valve clogged
• Open valve, force cleaning
drain from frypot
with crumbs
brush through drain
Filter switch on,
• Motor thermal
• Reset thermal switch per section
motor does not run
protector tripped
on Filter Pump Motor
Protector – Manual Reset
More detailed troubleshooting information is available in the Technical Manual, available at