Henny Penny OEA/OGA-323 User Manual
Page 61

Model OFE/OFG-321,322,323,324
4-3. SPECIAL PROGRAM
MODE (Continued)
d. Press the UP or Down buttons to select “2,*OFF*”, to
disable the auto-lift. This can be used to bypass the
auto-lift mechanism, if the auto-lift becomes disabled.
e. Press the UP or Down buttons to select “3,*ON*”, to
force the auto-lift feature, if the controls are not
detecting
the
auto-lift.
Program Code Change (SP-15)
This allows the operator to change the program code (factory
set at 1, 2, 3) used to access Product Programming, Special
Programming, Clock Set, Data Comm, and Heat Control
Modes.
a. Follow steps 1 and 2 above.
b. Press PROG until "SP-15" and "CHANGE, MGR
CODE? 1=YES” shows in display, along with “CODE”.
c. Press . “ENTER NEW CODE, P=DONE, I=QUIT”
shows in display. Press product buttons with new code.
d. If satisfied with code, press PROG. “REPEAT NEW
CODE, P=DONE, I=QUIT, shows in display. Press same
code buttons in step c.
e. If satisfied with code, press PROG. “*CODE
CHANGE*” shows in display.
f. If not satisfied with code, press INFO and
“*CANCELLED*” shows in display, then reverts back to
"SP-15" and "CHANGE, MGR CODE? 1=YES”. Then
the above steps can be repeated.
Usage Code Change (SP-16)
This allows the operator to change the reset usage code
(factory set at 1, 2, 3) to reset the usage amounts of each
product. See Review Usage step in Information Mode.
a. Follow steps 1 and 2 above.
b. Press PROG until SP-16" and "CHANGE, USG CODE ?
1=YES” shows in display, along with “USAGE”.
c. Press , “ENTER NEW CODE, P=DONE, I=QUIT”
shows in display. Press product buttons with new code.
d. If satisfied with code, press
PROG
. “REPEAT NEW
CODE, P=DONE, I=QUIT” shows in display. Press same
code buttons in step c.
1005 4-13