Henny Penny OEA/OGA-323 User Manual
Page 67

Model OFE/OFG-321,322,323,324
6-1. INFORMATION MODE
This mode gathers and stores historic information on the
FUNCTIONS
fryer and operator’s performance. Press and
at the same time and “*INFO MODE*” shows on display.
Press or to access the steps and press to
view the statistics within each step. Information Mode is
intended for technical use, but the operator can view the
following
information:
1.
E-LOG - last 11 errors and time they occurred
2.
LAST LOAD-L - information about the most recent
Cook Cycle, or the cycle presently in progress, on the left
basket
3.
LAST LOAD-R - information about the most recent
Cook Cycle, or the cycle presently in progress, on the
right
basket
4.
DAILY STATS - information for the last 7 days
5.
REVIEW USAGE- information accumulated since the
last time this data was manually reset
6.
INP A_VHDSF_M - provides test of fryer inputs
7.
OUTP - shows the state of heater and pressure
8.
OIL TMP - temperature of shortening
9.
CPU TMP - temperature of PC board
10.
ANALOG - status of controller’s a-to-d converter
11.
AUTOLIFT - shows status of autolift system (if
applicable)
Press and hold to exit Information Mode at
any time, or after 2 minutes, controls automatically exit
back to normal operation.
1.
E-LOG
(error code log)
Press and “1A. (date & time) *NOW*” shows in
display. This is the present date and time.
Press and if an error was recorded, “1B. (date, time, and
error code information)” shows in display. This is the latest
error code that the controls recorded.
1005
6-1
SECTION 6. INFORMATION MODE – 6 & 12 PRODUCT CONTROLS