Honeywell Granit 1991iSR Ultra-Rugged Standard-Range Barcode Scanner User Manual
Page 186
170
Granit XP User Guide
Default = Don’t Require Addenda.
EAN-13 Beginning with 977 Addenda Required
This setting programs the scanner to require a 2 digit addenda only on EAN-13
barcodes that begin with “977.” The following settings can be programmed:
Require 2 Digit Addenda
: All EAN-13 barcodes that begin with “977” must have a
2 digit addendum. The EAN-13 barcode with the 2 digit addendum is then trans-
mitted as a single, concatenated barcode. If a 2 digit addendum is not found within
the
period, the EAN-13 barcode is discarded.
Don’t Require 2 Digit Addenda
: If you have selected Require 2 Digit Addenda, and
you want to disable this feature, scan
Don’t Require 2 Digit Addenda
. EAN-13 bar-
codes are transmitted, depending on the setting you are using for
.
Default = Don’t Require 2 Digit Addenda.
EAN-13 Beginning with 978 Addenda Required
These settings program the scanner to require a 5 digit addenda only on EAN-13
barcodes that begin with “978.” The following settings can be programmed:
* Don’t Require Addenda
Require 2 Digit Addenda
Require 5 Digit Addenda
Require 2 or 5 Digit Addenda
* Don’t Require 2 Digit Addenda
Require 2 Digit Addenda