Partial sequence – Honeywell Granit 1991iSR Ultra-Rugged Standard-Range Barcode Scanner User Manual
Page 122

106
Granit XP User Guide
Partial Sequence
If an output sequence operation is terminated before all your output sequence cri-
teria are met, the barcode data acquired to that point is a “partial sequence.” You
can define how partial sequences are output using the same types of command
strings you used to create output sequences.
Partial Sequence Example - Three Symbologies with <> Separators, but with a
Damaged Code
In this example, you are scanning PDF417, Code 128, and Code 39 barcodes, and
you want the scanner to output Code 39 first, Code 128 second, and PDF417 third,
in brackets, as shown below, but the Code 39 barcode has been damaged and
cannot be output.
You would use the same command line as shown in
Three Symbologies with <> Separators
SEQBLK
sequence editor start command
62
code identifier for Code 39
9999
code length that must match for Code 39, 9999 = all
lengths
43
start character match for Code 39, 43h = "C"
FF
termination string for first code
6A
code identifier for Code 128
9999
code length that must match for Code 128, 9999 = all
lengths
54
start character match for Code 128, 54h = “T”
FF
termination string for first code
72
code identifier for PDF417
9999
code length that must match for PDF417, 9999 = all
lengths
4D
start character match for PDF417, 4Dh = “M”
FF
termination string for third code