Trigger number, Trigger timing, Trigger toggle timeout – Honeywell Granit 1991iSR Ultra-Rugged Standard-Range Barcode Scanner User Manual
Page 100

84
Granit XP User Guide
Trigger Number
This sets the number of trigger presses required to activate the Trigger Toggle
Mode.
Default is 3
.
Trigger Timing
This sets the timing of the trigger presses in order to qualify as a trigger toggle,
rather than a regular trigger press. After scanning the
Trigger Timing
barcode, set
the time-out duration (from 50-2,000 milliseconds) by scanning digits from the
Save
.
Default = 400ms.
Trigger Toggle Timeout
This sets the length of time the scanner stays in trigger toggle mode before revert-
ing to scan mode. After scanning the
Trigger Toggle Timeout
barcode, set the
time-out duration (from 0 to 65 seconds) by scanning digits from the
Save
.
Default = 5 seconds.
Note:
If this is set to 0, you must repeat the toggle sequence to return to the default
scanning mode. For example, if 2 quick trigger presses puts the scanner into
centering mode and the Trigger Timing is 0, you would have to do 2 quick presses
again to go back to the default scanning mode.
2 Quick Triggers
*3 Quick Triggers
4 Quick Triggers
Trigger Timing
Trigger Toggle Timeout