4.7.2.2 IGMP Interface Configuration

Figure 4-6-57

IGMP Interface Configuration

Selection Criteria

o

Slot/Port

- Select the slot and port for which data is to be displayed or configured from the pulldown menu. Slot 0 is

the base unit. You must have configured at least one router interface before configuring or displaying data for an

IGMP interface, otherwise an error message will be displayed.

Configurable Data

o

Interface Mode

- Select enable or disable from the pulldown menu to set the administrative status of IGMP on the

selected interface. The default is disable.

o

Version

- Enter the version of IGMP you want to configure on the selected interface. Valid values are 1 to 2 and the

default value is 2.

o

Robustness

- Enter the robustness value. This variable allows tuning for the expected packet loss on a subnet. If

you expect the subnet to be lossy, you should enter a higher number for this parameter. IGMP is robust to

(robustness variable-1) packet losses. Valid values are from 1 to 255. The default value is 2.

o

Query Interval

- Enter the frequency in seconds at which IGMP host-query packets are to be transmitted on this

interface. Valid values are from 1 to 3600. The default value is 125.