beautypg.com

129 mep dm ns, 130 mep dm overflow-reset – PLANET XGSW-28040HP User Manual

Page 244

background image

Command Guide of XGSW-28040HP

4.2.129 mep dm ns

Command:

mep dm ns

mep Maintenance Entity Point

The MEP instance number.

dm Delay Measurement

ns Nano Seconds

Default:

us

Usage Guide:

To configure Delay Measurement of MEP

Example:

To configure Delay Measurement unit (ns) of MEP 1 as below table.

Switch# configure terminal

Switch (config)# mep 1 dm ns

4.2.130 mep dm overflow-reset

Command:

mep dm overflow-reset

mep Maintenance Entity Point

The MEP instance number.

dm Delay Measurement

overflow-reset Reset all Delay Measurement results on total delay counter overflow.

Default:

Keep

Usage Guide:

To reset Delay Measurement of MEP while overflowing

Example:

To reset Delay Measurement of MEP 1 while overflowing

-244-

This manual is related to the following products: