beautypg.com

Avago Technologies 3ware SAS 9750-4i User Manual

Page 93

background image

Unit Object Commands

www.lsi.com/channel/products

85

/cx/ux show serial

This feature only applies to 9000 series controllers.

This command reports the unique serial number of the specified unit.

Example:

//localhost> /c0/u5 show serial

/c0/u5 Serial Number = 12345678901234567890

/cx/ux show status

This command reports the status of the specified unit.

Possible statuses include: OK, VERIFYING, VERIFY-PAUSED,
INITIALIZING, INIT-PAUSED, REBUILDING, REBUILD-PAUSED,
DEGRADED, MIGRATING, MIGRATE-PAUSED, RECOVERY,
INOPERABLE, and UNKNOWN. (Definitions of the unit statuses are
available in the 3ware SATA+SAS RAID Controller Card Software User
Guide, Version 10.0
.)

Example:

//localhost> /c0/u0 show status

/c0/u5 status = OK

/cx/ux show storsave

This feature only applies to 9750 model controllers and 9000 series SX/SE/
SA model controllers.

This command reports the storsave policy on the unit.

For more information see, “/cx/ux set storsave=protect|balance|perform
[quiet]” on page 95
.

Example:

//localhost> /c0/u5 show storsave

/c0/u5 Command Storsave Policy = protect

/cx/ux show verifystatus

This command reports the verifystatus (if any) of the specified unit.

Example:

//localhost> /c0/u5 show verifystatus

/c0/u5 is not verifying, its current state is OK