Cx rescan [noscan, Rescan [noscan – Avago Technologies 3ware SAS 9750-4i User Manual
Page 70

Chapter 2. CLI Syntax Reference
62
3ware SATA+SAS RAID Controller Card CLI Guide, Version 10.0
After the unit creation, a subsequent show command for the unit shows the
volume sizes:
//localhost> /c2/u0 show
Unit UnitType Status %RCmpl %V/I/M Port Stripe Size(GB)
------------------------------------------------------------------------
u0 RAID-0 OK - - - 256K 6519.19
u0-0 DISK OK - - p0 - 931.312
u0-1 DISK OK - - p1 - 931.312
u0-2 DISK OK - - p2 - 931.312
u0-3 DISK OK - - p4 - 931.312
u0-4 DISK OK - - p5 - 931.312
u0-5 DISK OK - - p6 - 931.312
u0-6 DISK OK - - p7 - 931.312
u0/v0 Volume - - - - - 2000
u0/v1 Volume - - - - - 500
u0/v2 Volume - - - - - 1024
u0/v3 Volume - - - - - 700
u0/v4 Volume - - - - - 1024
u0/v5 Volume - - - - - 1024
u0/v6 Volume - - - - - 247.188
/c
x
rescan [noscan]
This command instructs the controller to rescan all ports, vports, and phys and
reconstitute all units. The controller will update its list of disks, and attempts
to read every DCB (Disk Configuration Block) in order to re-assemble its
view and awareness of logical units. Any newly found unit(s) or drive(s) will
be listed.
noscan is used to not inform the operating system of the unit discovery. The
default is to inform the operating system.
Example:
//localhost> /c1 rescan
Rescanning controller /c1 for units and drives ...Done
Found following unit(s): [/c1/u3]
Found following drive(s): [/c1/p7, /c1/p8]
Note:
If you are adding new drives, add them physically before issuing the rescan
commands. Hot swap bays are required unless you first power-down the system to
prevent system hangs and electrical damage.