Raidtype, P:-p, Size – Avago Technologies 3ware SAS 9750-4i User Manual
Page 105: Migrate type, Disk, Noscan] [nocache] [autoverify

Unit Object Commands
www.lsi.com/channel/products
97
/c
x
/u
x
migrate type=
RaidType
[disk=
p:-p
]
[group=3|4|5|6|7|8|9|10|11|12|13|14|15|16]
[stripe=
size
] [noscan] [nocache] [autoverify]
This feature only applies to 9000 series controllers.
This command allows you to change the existing configuration of a unit with
type=RaidType. You can make three types of changes:
•
Increase the capacity
•
Change the RAID level (with the same or increased capacity)
•
Change the stripe size
The unit that results from the migration is subject to the same rules and
policies that apply when creating a new unit with the /cx add command. For
example, a valid number of disks and parameters must be specified.
The unit to be migrated must be in a normal state (not degraded, initializing,
or rebuilding) before starting the migration.
Note:
Rapid RAID Recovery is always disabled for units that are migrated.
The destination unit must use all source disks and potentially augment the
number of disks in the disk=p:-p disk list.. (An exception to this is when
migrating a RAID 1 to a unit of type single. For details, see the note below.)
Unspecified parameters are assigned the default values (stripe size of 64K,
write cache enabled, autoverify disabled, and ignoreECC disabled). Both
source name and serial number will be carried over to the destination unit.
Note:
A special case of this command is when the source unit has a type of
RAID1 and destination unit has a type of single. In this case, the migrate
command splits both drives into two identical single disks. (If you do this,
unmount the unit first before splitting). The disk name will be duplicated on
the destination units, but the source unit serial number will not be carried over
to the new unit. The new destination unit will have its own serial number. In
this case, the disk-specifier of the migration command [disk=p:-p] must not
be included in the command, because the source drives are the destination
drives. Specifying more drives with the disk= option would return an error
type=RaidType specifies the RAID type of the destination unit. Possible unit
types include raid0, raid1, raid5, raid6, raid10, raid50, or single.
For example, type=raid5 indicates the destination unit is RAID-5. The
type=single is a special case of the migrate command. It splits the source unit
RAID-1 or TWINSTOR into multiple Single units.
Note:
You can only migrate a unit to a RAID level that has the same or more
capacity as the existing one. A four-drive RAID 5 unit can migrate to a four-drive
RAID 0, but a four-drive RAID 0 unit cannot migrate to a four-drive RAID 5, without
adding another drive, due to the need for additional storage capacity for parity bits.