/cx/ux show rdcache

This command shows the current read cache state of the specified unit.

The state of the read cache can be either Basic, Intelligent, or Off. This
feature is supported on 9650SE and later controllers. This feature is supported
with all RAID array types. For more information, see “/cx/ux set
rdcache=basic|intelligent|off” on page 92

Example:

//localhost> /c0/u0 show rdcache

/c0/u0 Read Cache = Intelligent

/cx/ux show identify

This feature only applies to 9750 model controllers and 9000 series SX/SE/
SA model controllers. This feature requires a supported enclosure.

This command is related to the /cx/ux set identify=on|off

command. It shows

the identify status of the specified unit (either on or off).

Example:

//localhost> /c0/u0 show identify

/c0/u0 Identify status = on

/cx/ux show ignoreECC

This feature only applies to 9000 series controllers.

This command shows the current setting of the ignoreECC policy for the
specified unit.

Example:

//localhost> /c0/u0 show ignoreECC

/c0/u0 Ignore ECC policy = off

/cx/ux show initializestatus

This command reports the initializestatus (if any) of the specified unit.

Example:

//localhost> /c0/u5 show initializestatus

/c0/u5 is not initializing, its current state is OK

/cx/ux show name

This feature only applies to 9000 series controllers.

This command reports the name (if any) of the specified unit.

Example:

//localhost> /c0/u5 show name

/c0/u5 name = Joe