beautypg.com

Cx/ex/tempx set identify=on|off, Cx/ex/almx show, Cx/ex/almx set alarm=mute|unmute|off – Avago Technologies 3ware SAS 9750-4i User Manual

Page 140

background image

Chapter 2. CLI Syntax Reference

132

3ware SATA+SAS RAID Controller Card CLI Guide, Version 10.0

/c

x

/e

x

/temp

x

set identify=on|off

This command is used with 9750 and 9690SA controllers. For the 9650SE,
simply drop the prepended controller name in the command and use /ex.

If the enclosure supports Temperature Sensor Identify, this command causes
the LED associated with the temp sensor to blink, or turns off identification of
the LED for this temp sensor.

Example:

//localhost> /c0/e0/temp1 set identify=on

Setting Temperature Sensor Identify on /c0/e0/temp1 to [on] ...

Done.

/c

x

/e

x

/alm

x

show

This command is used with 9750 and 9690SA controllers. For the 9650SE,
simply drop the prepended controller name in the command and use /ex.

This command shows information about the specified enclosure alarm. The
possible status values are OK, FAIL, NOT-INSTALLED, and ACTIVATED.
The status values are described below. The possible values for State are ON
and OFF. The possible values for Audibility are UNMUTE and MUTED.

Possible Status values:

OK - Alarm device is functional and operational.

FAIL - Alarm device has malfunctioned and is not operational.

NOT-INSTALLED - Alarm device has not been installed.

ACTIVATED - Alarm device is functional, and an error condition has been
detected. This is a visual indication for the alarm, in addition to the sound. If
you mute the sound, this indication remains.

Example:

//localhost> /c0/e0/alm0 show

Alarm Status State Audibility

---------------------------------------------------

alm0 ACTIVATED OFF UNMUTE

/c

x

/e

x

/alm

x

set alarm=mute|unmute|off

This command is used with 9750 and 9690SA controllers. For the 9650SE,
simply drop the prepended controller name in the command and use /ex.

This command controls the audibility and state of the enclosure alarm. It
provides the ability to silence the alarm after it has activated. It also gives you
the option to mute or unmute the alarm setting.