beautypg.com

Cx/ex show, Show – Avago Technologies 3ware SAS 9750-4i User Manual

Page 131

background image

Enclosure Object and Element Commands

www.lsi.com/channel/products

123

/cx/ex/fanx set speed=<0|1|2|3|4|5|6|7>

/cx/ex/pwrsx show

/cx/ex/pwrsx/ show identify

/cx/ex/pwrsx set identify=on|off

/cx/ex/tempx show

/cx/ex/tempx show identify

/cx/ex/tempx set identify=on|off

/cx/ex/almx show

/cx/ex/almx set alarm=mute|unmute|off

/c

x

/e

x

show

This command is used with 9750 and 9690SA controllers. For the 9650SE
and CCU enclosure, simply drop the prepended controller name in the
command and use /ex.

This command shows summary information on the specified enclosure /cx/ex.
This report consists of several parts, depending on the available elements of
the enclosures. Typically, the summary consists of the Enclosure section
listing the set of enclosures, a Fan section, a Temperature Sensor section, a
Power Supply
section, a Slot section, and an Alarm section.

Example:

//localhost> /c0/e0 show

Encl Status

---------------------------

/c0/e0 OK

Fan Status State Step RPM Identify

------------------------------------------------------------

fan0 OK ON 1 2670 Off

fan1 OK ON 1 9500 Off

fan2 OK ON 1 8540 Off

fan3 OK ON 1 2830 Off

fan4 OK ON 1 9120 Off

fan5 OK ON 1 8330 Off

TempSensor Status Temperature Identify

--------------------------------------------------------

temp0 OK 41C(105F) Off

temp1 OK 38C(100F) Off

temp2 OK 34C(93F) Off

temp3 OK 38C(100F) Off

temp4 OK 38C(100F) Off

temp5 OK 34C(93F) Off

temp6 NOT-INSTALLED - Off

temp7 NOT-INSTALLED - Off

PowerSupply Status State Voltage Current Identify

---------------------------------------------------------------------------

pwrs0 OK on OK OK Off

pwrs1 OK on OK OK Off