beautypg.com

Cx/ux show, Show – Avago Technologies 3ware SAS 9750-4i User Manual

Page 88

background image

Chapter 2. CLI Syntax Reference

80

3ware SATA+SAS RAID Controller Card CLI Guide, Version 10.0

/c

x

/u

x

show

This command shows summary information about the specified unit /cx/ux. If
the unit consists of sub-units, as in the case of RAID-10 and RAID-50, then
each sub-unit is further presented. If the Auto-Carving policy was on at the
time the unit was created and the unit is over the carve size, multiple volumes
were created and are displayed at the end of the summary information.
Similarly, if the unit was created using the 3ware BIOS utility 3BM and a size
was entered in the Boot Volume Size field, multiple volumes were created and
will be displayed. Note that a volume created using the Boot Volume Size
feature does not have to be used as a boot volume.

Note:

In the output of unit information tables that follows, the column “Port”

may be “VPort” depending on the applicable controller.

Example for 9750 and 9690SA controllers:

//localhost> /c0/u1 show

Unit UnitType Status %RCmpl %V/I/M VPort Stripe Size(GB)

------------------------------------------------------------------------

u1 RAID-0 OK - - - 64K 3576.06

u1-0 DISK OK - - p0 - 298.01

u1-1 DISK OK - - p1 - 298.01

u1-2 DISK OK - - p2 - 298.01

u1-3 DISK OK - - p3 - 298.01

u1-4 DISK OK - - p4 - 298.01

u1-5 DISK OK - - p5 - 298.01

u1-6 DISK OK - - p6 - 298.01

u1-7 DISK OK - - p7 - 298.01

u1-8 DISK OK - - p8 - 298.01

u1-9 DISK OK - - p9 - 298.01

u1-10 DISK OK - - p10 - 298.01

u1-11 DISK OK - - p11 - 298.01

u1/v0 Volume - - - - - 2047.00

u1/v1 Volume - - - - - 1529.06

Example for 9650SE and earlier controllers:

//localhost> /c0/u0 show

Unit UnitType Status %RCmpl %V/I/M Port Stripe Size(GB)

------------------------------------------------------------------------

u0 RAID-50 OK - - - 64K 596.05

u0-0 RAID-5 OK - - - 64K -

u0-0-0 DISK OK - - p0 - 149.10

u0-0-1 DISK OK - - p2 - 149.10

u0-0-2 DISK OK - - p3 - 149.10

u0-1 RAID-5 OK - - - 64K -

u0-1-0 DISK OK - - p4 - 149.10

u0-1-1 DISK OK - - p5 - 149.10

u0-1-2 DISK OK - - p6 - 149.10

//localhost> /c0/u1 show

Unit UnitType Status %RCmpl %V/I/M Port Stripe Size(GB)

------------------------------------------------------------------------

u1 RAID-0 OK - - - 64K 3576.06

u1-0 DISK OK - - p0 - 298.01

u1-1 DISK OK - - p1 - 298.01