Chapter 2. CLI Syntax Reference
102
3ware SATA+SAS RAID Controller Card CLI Guide, Version 10.0
For example, below is a system with two migrating units, /c0/u0 and /c0/u1.
u0 is migrating from a RAID-10 to a RAID-0 array, while u1 is migrating
from Single to a RAID-1, initiated by the following commands:
/c0/u0 migrate type=raid0
/c0/u1 migrate type=raid1 disk=5
Note the difference in UnitType and Status of u0 and u1, even though they are
both migrating units.
3ware CLI> /c0 show
Unit UnitType Status %RCmpl %V/I/M Stripe Size(GB) Cache
AVrfy
-----------------------------------------------------------------------
----
u0 Migrator MIGRATING - 26 - 298.002 RiW OFF
u1 RAID-1 REBUILD-PAUSED 0 - - 372.519 OFF OFF
Port Status Unit Size Blocks Serial
----------------------------------------------------------------------
--
p0 OK u0 149.05 GB 312581808 WD-WCANM1883862
p1 OK u0 149.05 GB 312581808 WD-WCANM1754124
p2 OK u0 372.61 GB 781422768 WD-WMAMY1661939
p3 OK u0 372.61 GB 781422768 WD-WMAMY1579179
p4 OK u1 372.61 GB 781422768 WD-WMAMY1662720
p5 DEGRADED u1 372.61 GB 781422768 WD-WMAMY1576310
p6 NOT-PRESENT - - - -
p7 NOT-PRESENT - - - -
3ware CLI> /c0/u3 show
Unit UnitType Status %RCmpl %V/I/M Port Stripe Size(GB)
----------------------------------------------------------------------
--
u0 Migrator MIGRATING - 26 - - -
su0 RAID-10 OK - - - 64K 298.002
su0-0 RAID-1 OK - - - - -
su0-0-0 DISK OK - - p0 - 149.001
su0-0-1 DISK OK - - p1 - 149.001
su0-1 RAID-1 OK - - - - -
su0-1-0 DISK OK - - p2 - 149.001
su0-1-1 DISK OK - - p3 - 149.001
su0/v0 Volume - - - - - 298.002
du0 RAID-0 OK - - - 64K 596.004
du0-0 DISK OK - - p3 - 149.001
du0-1 DISK OK - - p2 - 149.001
du0-2 DISK OK - - p1 - 149.001
du0-3 DISK OK - - p0 - 149.001
du0/v0 Volume - - - - - N/A
3ware CLI> /c0/u1 show
Unit UnitType Status %RCmpl %V/I/M Port Stripe Size(GB)
----------------------------------------------------------------------
--