Show alarms [reverse, Show events [reverse, Show aens [reverse – Avago Technologies 3ware SAS 9750-4i User Manual
Page 35: Show diag, Show rebuild

Shell Object Commands
www.lsi.com/channel/products
27
Example for 9690SA-414E with enclosure and expander:
Typical output of the Show command for a system with an enclosure,
expander, and a 9690SA-4I4E controller looks like the following:
//localhost> show
Ctl Model (V)Ports Drives Units NotOpt RRate VRate BBU
---------------------------------------------------------------------------
c0 9690SA-4I4E 12 4 1 0 4 4 -
Encl Slots Drives Fans TSUnits PSUnits
---------------------------------------------------
/c0/e0 4 2 1 1 1
show alarms [reverse]
This command shows the controller alarms or events, also known as AEN
(Asynchronous Event Notification) messages, of all controllers in the system.
The default is to display the most recent messages at the bottom. The reverse
attribute displays the most recent message at the top. For more information,
see “/cx show alarms [reverse]” on page 46.
show events [reverse]
This command is the same as “show alarms [reverse]”. Please see above for
details.
show AENs [reverse]
This command is the same as “show alarms [reverse]”. Please see above for
details.
show diag
This command shows the diagnostic information of all controllers in the
system. The enclosure diagnostic log may be requested by 3ware Customer
Support to help troubleshoot problems on your controller.
show rebuild
This command displays all rebuild schedules for the 9000 series controllers in
the system.
The rebuild rate is also applicable for initializing, migrating, and recovery
background tasks.