C x /e x show temp, C x /e x show pwrs – Avago Technologies 3ware SAS 9750-4i User Manual
Page 134

Chapter 2. CLI Syntax Reference
126
3ware SATA+SAS RAID Controller Card CLI Guide, Version 10.0
Example:
//localhost> /c0/e0 show fans
---Speed---
Fan Status State Step RPM Identify
------------------------------------------------------------
fan0 OK ON 1 2670 Off
fan1 OK ON 1 9370 Off
fan2 OK ON 1 8540 Off
fan3 OK ON 1 2810 Off
fan4 OK ON 1 9240 Off
fan5 OK ON 1 8330 Off
/cx/ex show temp
This command is used with 9750 and 9690SA controllers. For the 9650SE,
simply drop the prepended controller name in the command and use /ex.
This command lists the temperature sensors in enclosure /cx/ex and the
current temperature.
Note:
The maximum temperature for successful use of a drive should be
noted in the documentation for the drive.
The TempSensor column lists the temperature sensor IDs, the Status column
lists the status of each temperature sensor, the Temperature column shows the
temperature at the sensors, and the Identify column lists the Identify setting of
the temperature sensors
Example:
//localhost> /c0/e0 show temp
TempSensor Status Temperature Identify
--------------------------------------------------------
temp0 OK 41C(105F) Off
temp1 OK 37C(98F) Off
temp2 OK 34C(93F) Off
temp3 OK 38C(100F) Off
temp4 OK 38C(100F) Off
temp5 OK 34C(93F) Off
temp6 NOT-INSTALLED - Off
temp7 NOT-INSTALLED - Off
/cx/ex show pwrs
This command is used with 9750 and 9690SA controllers. For the 9650SE,
simply drop the prepended controller name in the command and use /ex.
This command reports a summary of power supplies with their respective
information for the specified enclosure.
The PowerSupply column lists the IDs of the power supply units, the Status
column lists the status of each power supply, the State column indicate if the