beautypg.com

TA Triumph-Adler LP 4024 User Manual

Page 212

background image

RS-232C Protocol

C-8

H5: Protocol logic

The factory default setting is 0.

H6: Buffer nearly-full threshold

This is a percentage from 0 to 99. The factory default setting is 90.

H7: Buffer nearly-empty threshold

This is a percentage from 0 to 99. The factory setting is 70.
The factory default settings of the buffer nearly-full and nearly-empty

thresholds (H6 and H7) are subject to change without notification.
The gap between the nearly-full and nearly-empty thresholds allows the

computer to send a fairly large amount of data in a continuous stream.

H8: Received-data buffer size

This is the size of the input buffer, specified in units of 10 Kbytes. The

factory default setting is 6, meaning 60 Kbytes.

PRESCRIBE 2e FRPO D0 command

The PRESCRIBE 2e FRPO D0 command is provided to allow manipulating

XON/XOFF when an error has occured on the serial interface. The

following table summarizes the error status corresponding to different D0

values.

Parameter value

Meaning

0

Combination of 1 and 3 below

1

DTR, positive logic

2

DTR, negative logic

3

XON/XOFF

4

ETX/ACK

5

XON/XOFF recognized only as protocol

Timing of XON transfer to host
while Ready or Waiting

Serial interface error

Error not handled

Error handled

XON sent every 3 to 5 seconds

D0=0 (default)

D0=1

XON not sent

D0=10

D0=11