Novactive description & programming – RISCO Group Gardtec GT600 User Manual
Page 91
Page
89
GT 600 / 601 Engineer’s Reference Guide
NovActive Description & Programming
NovActive utilises a four core bus to the NovActive sounders that are fitted to the
system. This allows each individual Bell to to programmed and also gives access to
unique Diagnostic Features that allow the individual NovActive sounders to be
diagnosed from either the control panel or via GardTec Remote PC Software. GardTec
Remote may be used from either a remote location via a Modem or on-site via a
GardTec Modem Patch Lead.
To program the NovActive sounder(s) please follow the instructions below.
Wiring of the NovActive should be carried out in conjunction with the instructions
supplied with the unit.
1)
Enter into Engineer Mode
To do this follow Steps 1 to 4 on page 11
With the display showing:-
2)
Press No three times. The display will show:-
3)
Press Yes. The display will show:-
4)
Press Yes. The display will show:-
5)
Press No twice. The display will show:-
6)
Press Yes. The display will show:-
Program . . . . _ _ _
Zones ?
Program . . . . _ _ _
Bells / Sounders ?
Program Bell
Type ?
NovActive = Off
NovActive > On
Select NovActive
1 - 8