Programming bells / sounders – RISCO Group Gardtec GT600 User Manual
Page 41
Page
39
GT 600 / 601 Engineer’s Reference Guide
Programming Bells / Sounders
1)
Enter into Engineer Mode
To do this follow Steps 1 to 4 on page 11
With the display showing:-
2)
Press No three times. The display will show:-
3)
Press Yes. The display will show:-
4)
Press Yes. The display will show:-
5)
This option should remain Off unless you are
using a NovActive Bell Box
Press Yes. The display will show:-
Two Types of Bell may be programmed.
SAB
Self Actuating Bell. The Bell + terminal stands at 12V and the Bell -
terminal switches negative on activation.
SCB
Self Contained Bell. The Bell + and Bell - stand at 12V and 0v. The
0V is removed on activation.
The majority of Bells sold in the UK are SAB. You should only change the Bell
Type if you are sure the Bell Type you have is SCB.
The other option on this screen may be programmed as
Normal
Normal UK trigger for the UK
Irish
A 4k7 resistor is required in the tamper return line at the bellbox this
option is only required for the Irish Republic.
Program . . . . _ _ _
Zones ?
Program . . . . _ _ _
Bells / Sounders ?
Program Bell
Type ?
NovActive = Off
Type = SAB
Normal