beautypg.com

Programming bells / sounders – RISCO Group Gardtec GT600 User Manual

Page 41

background image

Page

39

GT 600 / 601 Engineer’s Reference Guide

Programming Bells / Sounders

1)

Enter into Engineer Mode
To do this follow Steps 1 to 4 on page 11
With the display showing:-

2)

Press No three times. The display will show:-

3)

Press Yes. The display will show:-

4)

Press Yes. The display will show:-

5)

This option should remain Off unless you are
using a NovActive Bell Box
Press Yes. The display will show:-

Two Types of Bell may be programmed.

SAB

Self Actuating Bell. The Bell + terminal stands at 12V and the Bell -
terminal switches negative on activation.

SCB

Self Contained Bell. The Bell + and Bell - stand at 12V and 0v. The
0V is removed on activation.

The majority of Bells sold in the UK are SAB. You should only change the Bell
Type if you are sure the Bell Type you have is SCB.

The other option on this screen may be programmed as

Normal

Normal UK trigger for the UK

Irish

A 4k7 resistor is required in the tamper return line at the bellbox this
option is only required for the Irish Republic.

Program . . . . _ _ _
Zones ?

Program . . . . _ _ _
Bells / Sounders ?

Program Bell
Type ?

NovActive = Off

Type = SAB

Normal