Page
55
GT 600 / 601 Engineer’s Reference Guide
50)
Press No until the required setting is displayed
then press Yes. The display will show:-
This option determines what Digi Channels will send a Restore Signal to Central
Station when the system is Reset. Most Central Stations will require a Restore
Report for all channels.
51)
Press No. The display will show:-
52)
Enter eight ones so the display shows:-
53)
Press Yes. The display will show:-
Channel 4 normally needs an inversion of the signal that is sent to Central
Station. By having 4 as the setting for this option channel 4 will be inverted. If
you have reports from the Central Station that the Open/Close channels are the
wrong way around proceed as follows to remove the inversion on the control
panel.
54)
If you do not need to change this option, press
Yes and jump to Step 56.
Or
To change the setting. Press No.
The display will show:-
55)
Press 0 followed by Yes. The display will show:-
Note: For EN requirements, a Test Call
MUST be sent to the Central Station once
every 24 Hrs. This can be found under advanced function, under Test Call Time.
Channel 1 2 3 4 5 6 7 8
R/Rep = 0 0 0 1 0 0 0 0
Channel 1 2 3 4 5 6 7 8
R/Rep = _ _ _ _ _ _ _ _
Channel 1 2 3 4 5 6 7 8
R/Rep = 1 1 1 1 1 1 1 1
Open/Close
Channel/s = 4
Open/Close
Channel/s > _ _
Program Advanced
Functions ?