Page – RISCO Group Gardtec GT600 User Manual
Page 102
Page
100
GT 600 / 601 Engineer’s Reference Guide
If 8(2 Wire) wiring option is required. (Depending on Version).
11)
With the display showing:-
Press No until 8(2 Wire) is displayed.
12)
The display will show:-
13)
Press Yes. The display will show:-
Zone Pairing.
If the 8(2 Wire) wiring mode is used then a zone must be used to monitor for Masking and Fault.
This is achieved by selecting Zone Pairing as on. Zone Pairing cannot be used in ELF1 or ELF2
wiring modes.
When using Zone Pairing each zone will have a corresponding paired zone that will be used for
Masking and Fault signals. This is done by using the Odd numbered zones for the normal alarm
detection and the Even numbered zones for Masking and Fault Detection. For example.
Please note that half the zones on the system would be lost for processing the Mask and Fault
signals and it would be more prudent to use the ELF1 or ELF2 modes as described previously.
14)
Press No until the setting you require is displayed.
Then press Yes. The display will show:-
15)
Press No twice. The display will show:-
16)
Press Yes. The display will show:-
On-Board Zones
>8 <2-Wire>
On-Board Pairing
= Off
On-Board Zones
=8
Alarm Zone
Zone 1
Zone 3
Zone 5
Zone 7
etc..
.
Pared Zone for Mask / Fault
Zone 2
Zone 4
Zone 6
Zone 8
Zone Expansion
= ZEX
Zone Expansion
> ID
ID Pairing
= Off