Reset of the factory defaults and entering Engineer Mode:-
Note:
It is
ESSENTIAL that a 4 6 Yes No reset is done to all new systems
before commencement of programming.
1)
Remove all power from the system for at least ten seconds
2)
Apply mains power to the control panel.
The display will show, for example:-
(Display will differ depending on panel version)
3)
Whilst this display is showing (the first five
seconds) press the keys shown in a, b, c or d
for the reset required. (E.g. 4 6 Yes No).
The display will show:-
This may show for several minutes.
4)
The display will then show:-
The display may differ from the sample shown.
Note:
Due to changes within the standards, the
GT600 is only BS or EN2
(GRADE 2) compliant.
Selecting 1:BS - Panel may be programmed to comply with the old BS4737 Standards. DD243
requirements will still apply.
Selecting 2:EN2 - Panel may be programmed to comply with EN50131-1 for Grade 2 Systems.
DD243 requirements will still apply.
Selecting 3:EN3 - Panel may be programmed to comply with EN50131-1 for Grade 3 Systems.
DD243 requirements will still apply
5)
Select 2:EN2.The display will then show:-
This may show for several minutes.
The display will then show:-
From Control Panel Version 2 ONLY.
6)
Select either 1 or 2 depending on which standard you require.
Page
3
GT 600 / 601 Engineer’s Reference Guide
Gardtec60x xx-xx
Please Wait
Select Standard
1:BS 2:EN2 3:EN3
Please Wait
Select PD6662
1: 2004 2: 2010
Version