Programming panic / duress – RISCO Group Gardtec GT600 User Manual
Page 61
Page
59
GT 600 / 601 Engineer’s Reference Guide
Programming Panic / Duress
Note: Duress is defaulted to Off and cannot be changed. Duress 7 is now no
longer available.
You should also check current legislation if Panic & Duress signals are allowed for the
grade of system that you are fitting.
1)
Enter into Engineer Mode
To do this follow Steps 1 to 4 on page 11
With the display showing:-
2)
Press No seven times. The display will show:-
3)
Press Yes. The display will show:-
It should be noted that with PA = Bells Only no PA signals will be sent to Central
Station.
Available setting for PA are
Bells Only
Activating a Panic will only sound the Bells.
Bells Always
Activating a Panic will Sound the Bells and send a signal
to Central Station provided that a Digi Channel is
programmed as Panic.
Silent Always
Activating a Panic will only send a signal to Central Station
providing that a Digi Channel has been programmed as
Panic.
Bells if LFlt
As Silent Always but will revert to Bells if a Linefault is
present.
Program . . . . _ _ _
Zones ?
Program . . . . _ _ _
Panic / Duress ?
PA = Bells Only
= Non-Testable