87)

To add more Zones to Sec. repeat from Step 85.

88)

When you have finished adding Zones to Sec.
press Yes. The display will show:-

Perimeter Zone:
Zones programmed as perimeter will activate the alarm as normal but will also
activate a comms channel programmed as perimeter.

89)

If you do not wish to enter Per. Zones press Yes
and jump to Step 94.

Otherwise

90)

Press No. The display will show:-

91)

Enter the Zone number you require for Per.
followed by Yes.
The display will show for example:-

92)

To add more Zones to Per. repeat from Step 90.

93)

When you have finished adding Zones to Per.
press Yes. The display will show, for example:-

94)

Press 0 (zero), then No. The display will show:-

DKnock/Arm/Log:
Zones on double knock are required to activate within the double knock time
window or stay active for fifteen seconds to generate an alarm condition.

Arm is used to program the zones to automatically re-arm after an activation.
It should be noted that a zone still violated when the system times out after
an alarm, will not re-armed.

Page

26

GT 600 / 601 Engineer’s Reference Guide

Per. None

Enter Zone # _ _ _
then +YES or -NO

Per. 002

Test None

Program Zone
DKnock / Arm / Log ?