GT 600 / 601 Engineer’s Reference Guide
39)
Press No. The display will show:-
Setting Confirmation uses the Strobe Light to confirm that the system has finally
set.
40)
Press Yes. The display will show:-
41)
Press the No key to scroll through the options.
Available options for Strobe Confirm are.
Off
Strobe Confirm is turned Off
Full-Set
The Strobe will Confirm only on a Full Set
Any-Set
The Strobe will Confirm on Any Set (Full or Part)
42)
When the required setting is displayed press Yes.
The display will show:-
43)
Press No. The display will show:-
Auto Part Set allows the system to decide if the Setting should be Full Set or
Part 1 Set. In order to use this option the Setting Mode for Full Set MUST be
Time+E/E and a Door Contact must be fitted to the door.
If the system sees the door open and close during a setting procedure the
system will Full Set.
If the system does not see the door open and close during a setting procedure
the system will Part 1 Set.
It is not possible to use Silent Part Sets with this option as the decision to do a
Part 1 set is taken after the Entry Time has expired.
Program Setting
Confirmation ?
Program Setting
Confirmation ?
Program Setting
for Auto-Part ?