RISCO Group Gardtec GT600 User Manual
Page 64
Page
62
GT 600 / 601 Engineer’s Reference Guide
cont-
Strobe
Latch Any
Any Set
Power-Fail
Power OK
Const. LoBat
(Radio Low Battery)
Radio Lost
(Lost Radio Detector etc)
Const. Jamm.
(Radio Signal Jamming)
Any Fault
Any Mask
Watchdog
Mains-Fail
Any-Digi
Status
Perimeter
Zon Exclude
Custom 1- 8
Off
Timed 1 - 3
Any-Closed
Pulse Off
Pulse On
After Alarm
Walktest
Pulse Set
Int. Sounder
E/E
Area variants of the above will also be displayed.
(Areas 4 to 7, 601 ONLY)
5)
Press No. The display will show:-
Choose from one of the options displayed. E.g. If 5
is selected PGM2 will operate when ANY detector
is triggered.
(Choose 1 - 7 for Areas, 8 All, 9 Any, 601 ONLY)
6)
The display will show:-
7)
Press No until the required setting is displayed,
then press Yes. The display will show, for example:-
With the PGM2 programmed as Bell the output will operate with the Bell when this is
set as +V. With this set as -V the output will be inverted e.g On, turning Off with the
Bell.
PGM2 O/P
>Bell =+V
Choose 1=A1 2=A2
3=A3 4=All 5=Any
PGM2 O/P
=Bell >+V