GT 600 / 601 Engineer’s Reference Guide
6)
Press Yes. The display will show:-
7)
Press No. The display will show:-
8)
Press Yes. The display will show:-
(Delay 1 indicates Area 1).
(Delay 4 to Delay 7, 601 ONLY).
9)
Press No twice. The display will show:-
10)
Enter the number of minutes you require for the
Bell Delay followed by Yes.
The display will show:-
Note: Bell Delay is defaulted to 0 but maybe programmed to a maximum of 10 minutes.
Be careful when using Bell delay, the Bell will not sound for the period
programmed after the alarm has been activated. Bell Delay used to be a Police
requirement, but is now not often used in the UK.
11)
Press No.The display will show:-
Number of Arms is the number of times the bell is capable of sounding during a
Set period. It is normal to set this option to 3 or 4, If left at 99 the number of
Arms is infinite.
12)
Enter the required Number of Arms followed by
Yes.
13)
Repeat Delay programming for all 3 Areas.
The display will show:-
(Areas 4 to Areas 7, 601 ONLY).
Program Bell
Type ?
Program Bell
Delay / No. Arms ?
Program Bell
Delay / No. Arms ?
Bell Delay1 = 00 m
No. Arms = 99
Bell Delay1 = _ _ m
No. Arms = 99
Bell Delay = 00 m
No. Arms > 99
Bell Delay = 00 m
No. Arms > _ _