2.1 Axis Move Commands

2 -25

Filter time constant

Figure 2.18 Positioning Time Delay When a Filter is Used

1. If the positioning time is set to 0, an alarm will occur in the motion program.
2. If the travel distance of any axis is 0, an alarm will be generated.

J

Programming Examples

The following illustration shows a programming example for SET TIME POSITIONING
(MVT) in ABS mode.

ABS;

MVT [axis1] 100 [axis2] 200 T1000;

axis 2

axis 1

Target position

200

Takes 1 s for travel

Current position

100

0

Figure 2.19 Programming Example for SET TIME POSITIONING (MVT)

2

IMPORTANT

A

EXAMPLE

"